RANCANG BANGUN RANQUE HILSCH VORTEX TUBE (RVHT)
Abstract
The purpose of this project is study the performance of vortex tube with the experiment analysis.the study is being tested in some variation conditions. As the pressure of air changes from 30,40,50 and 60psi and of different. Based from the experiment reasearchers found that the affecting factor of the vortex tube performance are the pressure of inlet air, the number of lines of nozzle ,and the angel of control valve. Using high pressure of inlet air the temperature at hot end will increase and decrease the temperature cool air in the cool end. According to the experiment found that by changing the inlet pressure. The result off the temperature is 13,86°C and the hottest air of 21,41°C using tipe Counter Flow . the tipe Uni Flow the best performance at 50 psi the temperature of different cold and hottest Outlet 2.8°C
Keywords: vortex tube, ratio value, cold temperature, Hot temperature,Compressor.
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
All articles published Open Access will be immediately and permanently free for everyone to read and download. We are continuously working with our author communities to select the best choice of license options, currently being defined for this journal as follows:
• Creative Commons Attribution-ShareAlike (CC BY-SA)