Efektivitas Liquid Suction Heat Exchanger (LSHX) pada Mesin Refrigerasi dengan R404A pada Berbagai Tingkat Subcooling

  • Andriyanto Setyawan Politeknik Negeri Bandung

Abstract

Liquid-to-suction heat exchanger has been used for air conditioning and refrigeration machines over years. It is aimed to increase the cooling capacity and coefficient of performance. In this research, the influence of LSHX utilization on a refrigerating machine with refrigerant R404a has been tested. The test was focused on the heat exchanger effectiveness under various evaporating temperature. To vary the evaporating temperature, a valve has been installed on the inlet side of thermostatic expansion valve. By varying the openings of this valve, the pressure of suction line could be varied from 30 psi to 50 psi, results in the evaporating temperatures from -24°C to -10°C. With the LSHX, the liquid refrigerant temperature could be lowered by 4°C to 8°C. The reduction of the temperature improves the capacity and coefficient to performance up to 16%. Based on the experimental results, the effectiveness of the LSHX ranges from 0.18 to 0.25. The lower the evaporating temperature gives the higher the effectiveness of the LSHX. However, subcooling and superheating should be limited to a certain value in order to control the compressor within safe operating conditions.

References

Granryd, E. Refrigeration Engineering. Royal Inst of Technology, 2009.

ASHRAE. ASHRAE Handbook of Fundamental, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta. 2013.

ASHRAE. ASHRAE Handbook of Refrigeration, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta. 2014.

S. Qian, J. Yu, G.A. Yan. A review of regenerative heat exchange methods for various cooling technologies. Renewable and Sustainable Energy Reviews. 2017; 69: 535–550.

McLinden, M.O. Optimum Refrigerants for Non-Ideal Cycles: An Analysis Employing Corresponding States. Proceedings ASHRAE – Purdue CFC and IIR – Purdue Refrigeration Conferences, W. Lafayette, July 17-20, 1990.

Domanski, P. A., and Didion, D. A. Thermodynamic Evaluation of R22 Alternative Refrigerants and Refrigerant Mixtures. ASHRAE Transactions, 1993; Vol. 99, No. 2: 636-648.

Domanski, P. A., Didion, D. A., and Doyle, J. P. Evaluation of Suction-Line/Liquid-Line Heat Exchange in the Refrigeration Cycle. Rev. Int. Froid. 1994; Vol. 17 ( 7): 487-493.

Domanski, P.A. Theoretical Evaluation of the Vapor Compression Cycle With a Liquid-Line/Suction-Line Heat Exchanger, Economizer, and Ejector. U.S. Department of Commerce. 1995.

Bittle, R. R., Stephenson, W. R., and Pate, M. B. An Experimental Evaluation of Capillary Tube-Liquid-suction Heat Exchanger Performance with R152a. ASHRAE Transactions, 1995; Vol. 101, No. 1: 124-135.

Bittle, R. R., Stephenson, W. R., and Pate, M. B. An Evaluation of the ASHRAE Method for Predicting Capillary Tube-Liquid-suction Heat Exchanger Performance. ASHRAE Transactions, 1995; Vol. 101, No. 2: 434-442.

Kim, M.H., Domanski, P.A., and Didion, D.A. Performance of R-22 Alternative Refrigerants in a System with Cross-flow and Counter-flow Heat Exchangers. U.S. Department of Energy. 1997.

Klein, S. A. and Reindl, D. T. The Relationship of Optimum Heat Exchanger Allocation and Minimum Entropy Generation Rate for Refrigeration Cycles. Transcaction of ASME. 1998; Vol. 23: 172-178.

YanaMotta, S.F., and Domanski, P.A. Performance of R22 and its alternatives working at high outdoor temperature. 8th International Congress of Refrigeration, Purdue University, 2000.

Li, X.Z., J. Che and P. Hrnjak, Effect of Internal Heat Exchanger on Performance of a R134a Mobile A/C System, International Congress of Refrigeration, Washington, D.C., 2003.

Dhanakitt, T. Energy Saving of Split-type Air Conditioners using Liquid-suction Heat Exchanger. Thesis, Department of Energy Technology, King Mongkut&quotes University of Technology Thonburi, Thailand; 2003.

Dagilis, V., Vaitkus L., and Balius, A. Liquid–gas heat exchanger for household refrigerator. International Journal of Refrigeration. 2004; 27 (3): 235-241.

Navarro-Esbrí, R. Cabello and Torrella, E. Experimental evaluation of the internal heat exchanger influence on a vapour compression plant energy efficiency working with R22, R134a and R407. Energy.2005; 30: 621-636.

Tambovtsev A., Quack H. Increasing the evaporation temperature with the help of an internal heat exchanger. Technische Universität Dresden, Dresden, Germany, 2000.

Mastrulloa, R., Mauroa, A.W., Tino, S. and Vanolia G.P. A chart for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system. Applied Thermal Engineering. 2007; 27 (14-15): 2443-2448.

Published
2018-11-24
How to Cite
Setyawan, A. (2018) “Efektivitas Liquid Suction Heat Exchanger (LSHX) pada Mesin Refrigerasi dengan R404A pada Berbagai Tingkat Subcooling”, ReTII. Available at: //journal.itny.ac.id/index.php/ReTII/article/view/939 (Accessed: 4December2024).